H13-H14 HEPA Deep Pleated Filter Introduction:
The HEPA Deep Pleated Filter normally used for final filtration applications in clean rooms, computer suites, asbsestos removal areas, hospital
operating theatres and any site requiring ultra clean conditions.
HEPA Deep Pleated Filter Construction:
The filter media is a water repellent pleated micro-glass fiber paper, each pleat is separated either by a kraft
paper or aluminium separator.
The completed pleat pack is then bonded into a frame which may be of high density particle board, galvanised
mild steel, stainless steel or aluminium. Neoprene gaskets may be fitted to either or both filter faces.
By extending the surface area it is possible to increase the flow rate for a given size of filter.
Approximately twice the flow rate may be achieved through the same size of HEPA filter by extending the surface area – this
is accompanied by a slight increase is pressure drop.Face grilles are available as an option.
Type | Absolute Deep Pleats HEPA Filter | ||
Brand | Haoairtech | ||
Efficiency | H13-H14 | ||
Frame | AL/GL /MDF Frame | ||
Sealant | AB GLUE | ||
Spacer | Hot Melt Glue | ||
Gasket | EPDM or EVA | ||
Standard | EN1822 | ||
Max Temperture | 80℃ | ||
Max. Humidity | 100% | ||
Frame thickness | 120-292mm | ||
Original Place | China |
Customer Size is Available.
Nominal Size
(W*H*D) |
Size (mm)(W*H*D) | Pleasts Type | Flange | Air Flow
(m3/h) |
Face Velocity | Primary Resistance (pa) |
Finally Resistance (Pa) |
12*12*6 | 305x305x150 | Deep Pleats AL Foile |
Two side | 360 | 1.3 | F6: 90Pa F7:130Pa F8:140pa F9:150Pa |
300Pa |
12*24*6 | 305x610x150 | Two side | 720 | 1.3 | |||
24*24*6 | 610x610x150 | Two side | 1680 | 1.3 | |||
30*24*6 | 762x610x292 | Two side | 2160 | 1.3 | |||
12*12*12 | 305x305x292 | Two side | 600 | 2.5 | |||
12*24*12 | 305x610x292 | Two side | 1320 | 2.5 | |||
24*24*12 | 610x610x292 | Two side | 3000 | 2.5 | |||
30*24*12 | 762x610x292 | Two side | 3600 | 2.5 |
Size | Rate air flow | Initial Resistance | Final Resistnace | Media Area | Dust Holding Capacity | Filter efficiency |
484x484x120 | 390 | 200 | 400-600 | 4.4 | 230 | H13 |
610x610x120 | 620 | 200 | 400-600 | 7.1 | 370 | H13 |
610x915x120 | 930 | 200 | 400-600 | 10.6 | 560 | H13 |
610x1220x120 | 1500 | 200 | 400-600 | 14.1 | 740 | H13 |
484x484x150 | 530 | 200 | 400-600 | 6 | 320 | H13 |
610x610x150 | 1000 | 200 | 400-600 | 9.7 | 510 | H13 |
610x915x150 | 1500 | 200 | 400-600 | 14.5 | 770 | H13 |
610x1220x150 | 2000 | 200 | 400-600 | 19.3 | 1020 | H13 |
484x484x220 | 1000 | 200 | 400-600 | 9.8 | 600 | H13 |
610x610x220 | 1600 | 200 | 400-600 | 15.8 | 920 | H13 |
610x915x220 | 2300 | 200 | 400-600 | 23.7 | 1340 | H13 |
610x1220x220 | 3000 | 200 | 400-600 | 31.6 | 1750 | H13 |